SYENSQO

Galden® D03 PFPE Electronic Testing Fluid

Galden® D03 is a high-boiling PFPE electronic testing fluid in the Galden® Electronic Fluids family. It offers excellent chemical inertness, electrical insulation and thermal stability for reliability testing of electronic components. In hermetic seal testing, electronic devices must be properly sealed to prevent moisture ingress and potential damage to electrical performance. Galden® PFPE fluids are particularly suitable because they are extremely inert and residue-free. D03 is mainly used as a high-boiling indicator fluid in leak-testing procedures. Galden® D03 is also used in thermal shock testing. With a typical boiling point of approximately 203°C and a pour point of approximately -85°C, it is suitable for demanding temperature-cycling test conditions.

CategoryColoring inspection agents
BrandSYENSQO
Colorclear liquid
Specification5KG
ApplicationA chemically inert PFPE fluid for hermetic seal testing and thermal shock testing of semiconductor and electronic devices requiring high electrical insulation and residue-free performance.

Product Details

Product Features

Excellent Chemical Inertness:PFPE chemistry provides high chemical stability for demanding electronic testing environments. 

High Electrical Insulation:Typical dielectric strength is approximately 40 kV at a 2.54 mm gap, with a dielectric constant of about 2.1. 

High Boiling Point:A typical boiling point of 203°C helps reduce evaporation losses and fluid consumption during testing. 

Low Surface Tension:Surface tension of approximately 16 dyne/cm supports penetration into small gaps and leak paths.

Residue-Free Testing:Galden® PFPE electronic fluids are designed for clean electronic reliability testing with minimal residue. 

 

Product Applications

Hermetic Seal Testing:Used as an indicator fluid in leak-testing procedures for sealed electronic devices. 

Semiconductor Package Testing:Suitable for reliability testing of integrated circuits and sealed semiconductor packages.

Thermal Shock Testing:Used as a test fluid for thermal shock and temperature-cycling evaluation of electronic components. 

High-Reliability Electronics:Applicable to electronics requiring stringent seal-integrity testing.

Item Galden® D03
Product Type PFPE Electronic Testing Fluid
Product Family Galden® PFPE Electronic Fluids
Model D03
Main Applications Hermetic Seal Testing / Thermal Shock Testing
Typical Boiling Point 203°C
Pour Point -85°C
Density @ 25°C 1.79 g/cm³
Density @ 125°C 1.58 g/cm³
Kinematic Viscosity @ 25°C 2.4 cSt
Kinematic Viscosity @ 125°C 0.55 cSt
Specific Heat @ 25°C 973 J/(kg·°C)
Thermal Conductivity @ 25°C 0.07 W/(m·°C)
Coefficient of Expansion 0.0011 cm³/(cm³·°C)
Surface Tension 16 dyne/cm
Dielectric Strength 40 kV (2.54 mm gap)
Dielectric Constant 2.1
Volume Resistivity 5×10¹⁵ Ω·cm
Average Molecular Weight 870 amu